Accelerated Aging Test Chamber / Laboratory Combustion Burn in Chamber for Television

Customization: Available
Max Diameter of Workpiece: 3200mm
Mass Scope of Workpiece: 6000kg

Products Details

Basic Info.

Model NO.
KU-504L
Type
Material Testing Machine
Maxcapacity
<1000KN
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Computer Control
Weight
100-500Kg
Power Source
AC380V
Oil Cylinder Position
Under
Capacity(Kw)
11
Chamber Volume(L)
504
Inner Size (D*W*H)
800*700*900mm
Temperature Range
-40oc~+150oc
Humidity Constancy
+/-0.5%
Cooling Rate
0.7oc~1.0oc/Min
Pressure Range
Normal Pressure~1kp
Pressurized Parts
High Quality Steel Plate(Rust Proof&Plastic Spray
Insulation Material
High Quality Glass Wool
Pump
Rotary Vane Type Vacuum Pump
Transport Package
Strong Plywood Case, Meet International Standards
Specification
Standard and Customized
Trademark
KOMEG
Origin
Dongguan, China
HS Code
90321000
Production Capacity
100-500kg

Product Description

Accelerated Aging Test Chamber / Laboratory Combustion Burn In Chamber For Television

OEM &ODM are welcome , more information , pls kindly contact:[email protected] 

Accelerated Aging Test Chamber / Laboratory Combustion Burn in Chamber for TelevisionAccelerated Aging Test Chamber / Laboratory Combustion Burn in Chamber for Television

Specification
 
1. SUS#304 stainless steel
 
2. Standard modular design
 
3. Waterproof and attactive
 
4. Security, stability, and reliable
 
5. Unique design of the wind cycle
 
Technical specification 
 

1. Temperature
 

1.1 Temperature range

-40ºC ~ +150ºC
 

1.2 Temp Deviation

<= ± 2.0ºC
 

1.3 Temp Fluctuation

±0.5ºC
 

1.4 Temp Uniformity

±2.0ºC
 

1.5 Heating and Cooling rate :
 
Heating rate: from -40ºC to +100ºC about 45 minutes ( no load, ambient temperature +25CºC)
 
Cooling rate :from +20ºC to down -40ºC about 60 minutes ( no load, ambient temperature +25ºC)
 

 

2. Humidity
 

2.1 Humidity range 10%R.H~98%R.H
3.3 Humidity deviation

±3.0%RH(>75%RH)
 
±5.0%RH(≤75%RH)

3.4 Humidity uniformity

3.0%RH (no-load)
 

3.5 Humidity fluctuation

±2.0%RH
 

Temperature and humidity performance test is in accordance with the relevant provisions of the
 
IEC60068 -3 standard measurement; sensor placed in the unit outlet.

Accelerated Aging Test Chamber / Laboratory Combustion Burn in Chamber for TelevisionAccelerated Aging Test Chamber / Laboratory Combustion Burn in Chamber for TelevisionAccelerated Aging Test Chamber / Laboratory Combustion Burn in Chamber for Television