- Overview
- Product Description
- Features
- Specifications
- Detailed Photos
- Related Product
- Company Profile
Basic Info.
Packaging & Delivery
Product Description
Drug /Medicine /Pharmaceutical Stability Test ChamberProducteatur
The new generation of drug stability testing equipment integrates years of design and production experience of the company, and introduces and digests German technology. Breaking through the defect of existing domestically produced drug test boxes being unable to operate continuously for a long time is a GMP certified equipment for pharmaceutical factories.
Usage Overview:
Creating a scientifically stable temperature, humidity, and lighting environment for drug failure evaluation is suitable for pharmaceutical companies to conduct accelerated, long-term, high humidity, and strong light exposure tests on drugs and new drugs. It is a suitable choice for pharmaceutical companies to conduct drug stability tests.
Humanized design
- A brand new fluorine-free design, with high efficiency, low energy consumption, and energy conservation, keeps you at the forefront of healthy living.
- A microcomputer controller with stable, accurate, and reliable control, using a 304 stainless steel inner liner and a semicircular arc at the four corners, easy to clean and easy to operate.
- Air duct circulation ensures uniform distribution of wind power within the studio. There is a 25mm diameter test hole on the left side of the box.
- Two sets of imported compressors automatically switch to ensure long-term continuous operation of drug testing without any malfunctions. Breaking through the defect of domestic drug test boxes being unable to operate continuously for a long time.
- Continuous operation does not require defrosting to avoid fluctuations in temperature and humidity inside the box during use due to defrosting.
- Key components such as temperature and humidity controllers, compressors, and circulating fans are all imported products, which have the characteristics of stable, safe, and reliable long-term operation.
- An independent temperature limit alarm system can provide audible and visual alarms to remind operators, ensuring safe operation of the laboratory without accidents.
- Alarm for low or high temperature and over temperature, and alarm for high or low humidity.
- Equipped with password lock screen function to prevent non experimental personnel from misoperating.
- Select a humidity sensor that can operate at high temperatures to avoid the troubles caused by frequent replacement of wet and dry bulbs.
- The ultraviolet sterilization lamp is placed on the back wall of the box, which can regularly disinfect the inside of the box, effectively killing floating bacteria in the circulating air and humidified water vapor inside the box, thereby effectively preventing pollution during drug testing.
- Breaking through the shortcomings of existing domestically produced stability test boxes that cannot monitor and control the light intensity, a light sensor is used for monitoring and stepless adjustment, reducing the attenuation of light intensity and test errors caused by lamp tube aging.
- When the test box malfunctions, the dynamic display screen will display fault information, and the operating faults of the test box are clear at a glance.
- It can be connected to a printer or 485 communication interface, and temperature and time curves can be recorded using a computer and printer, providing strong guarantee for data storage and playback during the test process.
- Programmable touch screen controller
- Adopting a large touch screen screen, the screen operation is simple and the program editing is easy.
- The controller operation interface is available in both Chinese and English for selection, and the real-time operation curve can be displayed on the screen.
- It has a capacity of 100 sets of programs, 1000 segments, and 999 cycle steps.
- After inputting data and test conditions, the controller has a screen locking function to avoid manual touch and shutdown.
- Equipped with P.I.D automatic calculation function, it can immediately correct temperature and humidity changes, making temperature and humidity control more accurate and stable.
- Equipped with RS-232 or RS-485 communication interface, it can design programs on a computer, monitor the testing process, and perform functions such as switching on and off.
- Guidelines for Drug Stability Testing in the 2020 Pharmacopoeia and Relevant Articles of GB/T10586-2006 Manufacturing
- Accelerated test: 40 ºC± 2.0 ºC/75% RH ± 5% RH, or 30 ºC± 1.0 ºC/60% RH ± 5% RH for 180 days
- Long term test: 25 ºC± 2.0 ºC/60% RH ± 5% RH, or/30 ºC± 2.0 ºC/60% RH ± 5% RH for 365 days
- For accelerated testing of drug formulations packaged in semi permeable containers, such as infusion bags prepared from low density polyethylene glycol, plastic ampoules, and eye preparation containers, the test should be conducted at a temperature of 40 ºC± 2 ºC/25% ± 5% RH
- For long-term testing of drug formulations packaged in semi permeable containers, the test should be conducted at a temperature of 25 ºC soil 2 ºC/40% ± 5% RH or 30 ºC ± 2 ºC/35% ± 5% RH
- Strong light exposure test: 4500 ± 500LX for 10 days
★ Storage conditions for long-term stability test of retention samples:
Temperature:+25 ºC± 2 ºC Humidity: 60 ± 5% RH
Time: 12 months
★ Storage conditions for accelerated stability testing
Temperature:+40 ºC± 2 ºC Humidity: 75 ± 5% RH
Time: 6 months Strong light exposure conditions Illuminance: 4500 ± 500LX
The above relevant data is for reference only, and the corresponding test environment temperature is 25 ºC
Technical Parameter
name | Drug Stability Test Chamber | Comprehensive drug stability test box | Drug Strong Light Stability Test Box | ||
model | LHH-80SD LHH-150SD LHH-250SD | LHH-80SDP LHH-150SDP LHH-250SDP | LHH-150GSD LHH-150GSP LHH-250GSD LHH-250GSP | LHH-150GP LHH-250GP LHH-400GP | |
temperature range | 0~65ºC | 0~65ºC(Illuminated 15~50ºC) | |||
Temperature fluctuation/uniformity | ±0.5ºC/±2ºC | ||||
Humidity range/deviation | 25~95%RH/±3%RH | nothing | |||
Light intensity/error | nothing | 0~6000LX adjustable ≤ ± 500LX (infinite dimming) | |||
Timing range | 1-99 hours per segment | ||||
Temperature and humidity control method | BTHC | Balanced temperature regulation method | |||
Refrigeration system/refrigeration method | Two sets of independent original imported fully enclosed compressors automatically switch (LHH-80SD/80SDP is a set of independent original fully enclosed compressors) | ||||
controller | Programmable touch screen controller | ||||
sensor | Pt100 platinum resistor Capacitive humidity sensor | Pt100 platinum resistor | |||
Working environment temperature | +5~30ºC | ||||
source | AC220V±10% 50HZ | ||||
Operating power | About 650W/680W/750W | About 680W/680W/750W/750W | About 450W/450W/600W | ||
power | 2000W/2800W/3000W | 2950W/2950W/3200W/3200W | 1450W/1700W/3200W | ||
volume | 80L 150L 250L | 80L 150L 250L | 150L 250L | 150L 250L 400L | |
Inner Tank Size (mm) W×D×H | 400×400×500 550×405×670 600×500×830 | 400×400×500 550×405×670 600×500×830 | 550×405×670 600×500×830 | 550×405×670 600×500×830 700×550×1140 | |
Overall dimensions (mm) W×D×H | 550×790×1080 690×805×1530 740×890×1680 | 550×790×1080 690×805×1530 740×890×1680 | 690×805×1530 740×890×1680 | 690×805×1530 740×890×1680 950×850×1850 | |
Load tray (standard) | 2/3/3 blocks | 2/3/3 blocks | 2/3/3 blocks | 2/3/3 blocks | |
Embedded printer | standard configuration | standard configuration | standard configuration | standard configuration | |
Safety devices | Compressor overheat protection, fan overheat protection, overtemperature protection, compressor overpressure protection, overload protection, and water shortage protection. | ||||
Remarks | 1. Standard 485 interface and embedded printer 2. SDP, GSP standard USB interface and wireless alarm system SD, GSD, GP series optional 3. GP, GSD, GSP series, manual stepless dimming, standard light intensity monitor, built-in top illuminator 4. GP, GSD, GSP series, optional with two-layer illuminator 5. LHH-80SD and LHH-80SDP are a set of independent original fully enclosed imported compressors |
![Drug /Medicine /Pharmaceutical Stability Test Chamber](http://img9.grofrom.com/www.dortestequipmentco.com/226f3j00mWLcUQuEhdov/Drug-Medicine-Pharmaceutical-Stability-Test-Chamber.webp)
![Drug /Medicine /Pharmaceutical Stability Test Chamber](http://img9.grofrom.com/www.dortestequipmentco.com/226f3j00miDoUzpPAAkM/Drug-Medicine-Pharmaceutical-Stability-Test-Chamber.webp)
![Drug /Medicine /Pharmaceutical Stability Test Chamber](http://img9.grofrom.com/www.dortestequipmentco.com/226f3j00wBvclFQrfzkh/Drug-Medicine-Pharmaceutical-Stability-Test-Chamber.webp)
![Drug /Medicine /Pharmaceutical Stability Test Chamber](http://img9.grofrom.com/www.dortestequipmentco.com/226f3j00aveciETJgubq/Drug-Medicine-Pharmaceutical-Stability-Test-Chamber.webp)
![Drug /Medicine /Pharmaceutical Stability Test Chamber](http://img9.grofrom.com/www.dortestequipmentco.com/226f3j00EvBbhgaGvucq/Drug-Medicine-Pharmaceutical-Stability-Test-Chamber.webp)
![Drug /Medicine /Pharmaceutical Stability Test Chamber](http://img9.grofrom.com/www.dortestequipmentco.com/226f3j00TBvoiWEybgbk/Drug-Medicine-Pharmaceutical-Stability-Test-Chamber.webp)
![Drug /Medicine /Pharmaceutical Stability Test Chamber](http://img9.grofrom.com/www.dortestequipmentco.com/226f3j00EeCcVBQhHgqk/Drug-Medicine-Pharmaceutical-Stability-Test-Chamber.webp)