Basic Info.
Model NO.
ESS-225LL5
Temp. Range
-70oc~+100oc
Temp. Constancy
+/-3.0oc
Interior Material
Stainless Steel Plate(SUS304)
Exterrior Material
Baked Painting Steel or Stainless Steel (SUS304)
Insulation Material
Rigid Polyurethane Foam+Glass Fiber Wool
Compressor
France Imported Tecumseh Semi-Hermetic Compressor
Cooling Mode
Water Cooled
Interior Dimension
W700*H700*D480mm
Transport Package
Strong Plywood Case, Meet International Standards
Specification
Standard and Customized
Trademark
KOMEG
Origin
Donguan, China
HS Code
90321000
Production Capacity
1000 Sets Per Yesr
Product Description
International Standards SGS UL Laboratory Rapid Temp/Change Chamber (ESS-225LL5)
Why KOMEG?
1. Specializing in environmental test chamber for 32years
2. Valued customers:HUAWEI, TCL, EMERSON, Epson, OMRON, GREE, SGS, FOXCONN, etc.
3. Imported Tecumseh Features
4. Touch Screen Controller
5. One year free parts warranty
6. Customized sizes and configurations available
Applications
Temperature adaptability test under the condition of rapid change, or gradient for electrical, electronic, instruments and other products or spareparts, particularly applies to environmental stress screening test(ESS)
Features
1.Rational Construction and fast cooling rate
2.Frequency conversion control of wind speed.
3.Adopts international brand of imported parts for cooling system to improve operation reliability
4.Touch screen controller, friendly Man-Machine interface and safety device to ensure simple operation and easy maintenance.
Controller
1.Temperature control adopts imported touch button type instrument, simple operation setting.(Japan RKC waalwijk)
2.After input data and test conditions, controller with locking function, avoid human touch and temperature change.
3.With the function of automatic calculus of P.I.D, can be corrected the temperature change conditions mmediately, make more accurate and stable temperature control.
4.Optional printer.
Frozen and the wind road system
1.Chiller adopting French "Taikang" enclosed totally compressor.
2.The refrigeration system use unit or binary type low temperature circuit system.
3.Adopt more wing type blower air supply cycle, to avoid any dead space, can make the uniform temperature distribute in the test area.
4.The wind circle with outlet air and return air design, the wind velocity are accord with test standard, and can make the door instantaneous temperature stabilizing time fast.
5.Completely independent of heating, cooling, system can improve the efficiency and reduce test cost, increase longevity, reduce the failure rate.
Meet The Standards
GB10592-89 Technical requirements for high and low temperature test chamber
GB2423.1-1989 Low temperature test
GB2423.2-1989 High temperature test mode
![International Standards SGS UL Laboratory Rapid Temp/Change Chamber (ESS-225LL5)](http://img9.grofrom.com/www.dortestequipmentco.com/226f3j00LSQPnVThnJUd/International-Standards-SGS-UL-Laboratory-Rapid-Temp-Change-Chamber-ESS-225LL5-.webp)
Operating technical parameter
Specifications | |||||||||||||
Model | ESS-SL | ESS-LL | |||||||||||
225SL5 | 225SL10 | 408SL5 | 408SL10 | 1000SL5 | 1000SL10 | 1000SL15 | 225LL5 | 225LL10 | 408LL5 | 408LL10 | 1000LL5 | 1000LL10 | |
Working Chamber Volume(L) | 225 | 408 | 1000 | 225 | 408 | 1000 | |||||||
Temp Rate of Change( ºC/Min) | 5 | 10 | 5 | 10 | 5 | 10 | 15 | 5 | 10 | 5 | 10 | 5 | 10 |
Performance | -70ºC~+100ºC | -70ºC~+100ºC | |||||||||||
Rapid Temp Change -55ºC~+85ºC Full Linear Control | Rapid Temp Change -40ºC~+85ºC Full Linear Control | ||||||||||||
Humidity Constancy | ±0.5ºC | ||||||||||||
Temp Constancy | ±3.0ºC | ||||||||||||
Exterior Material | Cold-rolled steel sheet (Rust proof & Plastic Spray treated )/ Stainless Steel | ||||||||||||
Interior Material | Stainless Steel Plate(SUS 304) | ||||||||||||
Insulation Material | Rigid Polyurethane Foam | ||||||||||||
Safety Devices | over pressure, over heat and over current protection for compressor, over temp. protection | ||||||||||||
Compressor | Semi-Hermetic Compressor | ||||||||||||
Cooling Mode | Water Cooled | ||||||||||||
Control system | Balanced Temperature & Humidity Control System(BTC type) | ||||||||||||
Heater | Iron-chrome wire heater | ||||||||||||
Blower | Centrifugal Blower | ||||||||||||
Observation Window | Glass incorporating heat generator | ||||||||||||
Temp Sensor | Pt-100 | ||||||||||||
Controller | Touch screen programmable controller | ||||||||||||
Ambient Temp. | +5ºC~+35ºC | ||||||||||||
Power | AC 380V/50Hz 3phase 5 wires+ Ground wire | ||||||||||||
Note: 1. We reserve the right to change specifications without prior notice 2. Customized sizes and configurations available |
![International Standards SGS UL Laboratory Rapid Temp/Change Chamber (ESS-225LL5)](http://img9.grofrom.com/www.dortestequipmentco.com/226f3j00DStINMElEJfA/International-Standards-SGS-UL-Laboratory-Rapid-Temp-Change-Chamber-ESS-225LL5-.webp)
Cooperated customers' feedback about why choose KOMEG
![International Standards SGS UL Laboratory Rapid Temp/Change Chamber (ESS-225LL5)](http://img9.grofrom.com/www.dortestequipmentco.com/226f3j00DZQHNyEBlwfd/International-Standards-SGS-UL-Laboratory-Rapid-Temp-Change-Chamber-ESS-225LL5-.webp)
![International Standards SGS UL Laboratory Rapid Temp/Change Chamber (ESS-225LL5)](http://img9.grofrom.com/www.dortestequipmentco.com/226f3j00WZtPOQTaYmGA/International-Standards-SGS-UL-Laboratory-Rapid-Temp-Change-Chamber-ESS-225LL5-.webp)
![International Standards SGS UL Laboratory Rapid Temp/Change Chamber (ESS-225LL5)](http://img9.grofrom.com/www.dortestequipmentco.com/226f3j00iZQPNgTrbdUA/International-Standards-SGS-UL-Laboratory-Rapid-Temp-Change-Chamber-ESS-225LL5-.webp)
![International Standards SGS UL Laboratory Rapid Temp/Change Chamber (ESS-225LL5)](http://img9.grofrom.com/www.dortestequipmentco.com/226f3j00VjEHNiQtbmGJ/International-Standards-SGS-UL-Laboratory-Rapid-Temp-Change-Chamber-ESS-225LL5-.webp)
![International Standards SGS UL Laboratory Rapid Temp/Change Chamber (ESS-225LL5)](http://img9.grofrom.com/www.dortestequipmentco.com/226f3j00VKTHNvthfwRd/International-Standards-SGS-UL-Laboratory-Rapid-Temp-Change-Chamber-ESS-225LL5-.webp)
After-sale service
If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days.We can offer operation video and English operation muanual.We can provide video-conference.If customers require on-site service, the transport and travel expense shall be borne by customer.