Basic Info.
Model NO.
JTSM-B/S/E Series
Certification
CE
Warranty
1 Year
Temperature Exposure Range
+50ºC~+150ºC
Temperature Fluctuation
± 0.5 ºC
Temperature Deviation
± 2 ºC
Temperature Uniformity
2 ºC
Transport Package
Wood Case
Specification
50L / 100L /150L / 200L / Customized
Trademark
Jupiter
Origin
China
Product Description
Temperature Shock Chamber with Two Chambers
Introduction
Such a series of impact test chamber adopts a structure of cold and thermal chambers and utilizes a bucket rapidly transforming specimens to the test area, so as to conduct cold and thermal shock tests.
This impact mode reduces thermal load during cold and thermal impact and shortens temperature recovery time to the greatest extent.
Feature
- This series chamber using cold and heat two chambers structure, mainly used for hot and cold temperature impact test material in an instant, in a very short period of time test caused by heat bilges cold shrink can bear by chemical or physical damage.
- 7 inches large color touch screen program control, running status be clear at a glance.
- The user can save 50 to edit test procedure, also has a record of 365 days parameter function (equipped with paperless recorder).
- In accordance with the requirements of recovery time, automatic equipment precooling, preheating temperature, adjust the working status of test cases to be the best.
- Low error, the wind speed is high, the uniform sample exposure.
- Province energy consumption, low noise design.
- Shopping basket conversion time is less than 10 seconds, temperature recovery time for 5 minutes.
- High temperature and low temperature zone can be independently controlled respectively, three with a chamber.
- GJB150.3, GJB150.4, GJB150.5 ...
Temperature Shock Chamber(Two Chamber) | |||||||||
Model | JTS50M-B/S/E | TS100M-B/S/E | JTS150M-B/S/E | JTS200M-B/S/E | JTS320M-B/S/E | JTS500M-B/S/E | JTS1000M-B/S/E | ||
Nominal inside volume(L) | 50L | 100L | 150L | 200L | 320L | 500L | 1000L | ||
Performance Parameter | Heating chamber | Temperature exposure range | +50ºC~+150ºC | ||||||
Upper limit of preheating temperature | 200ºC | ||||||||
Heating time | RT~+200ºC, B type: ≤ 50min; S type: ≤ 40min; E type: ≤ 30min | ||||||||
Cooling chamber | Temperature exposure range | B type: 0~-40ºC; S type: 0~-55ºC; E type: 0~-65ºC | |||||||
Lower limit of pre cooling temperature | -75ºC | ||||||||
Cooling time | RT~+70ºC, B type: ≤ 60min; S type: ≤ 50min; E type: ≤ 40min | ||||||||
Hand basket | Temperature shock range | B type:-40ºC~+150ºC; S type: -55ºC~+150ºC; E type: -65ºC~+150ºC | |||||||
Temperature fluctuation | ≤±0.5 | ||||||||
Temperature uniformity | ≤2ºC | ||||||||
Temperature deviation | ≤±2ºC | ||||||||
Conversion time | ≤10s | ||||||||
Temperature recovery time | 5 min | ||||||||
Load (steel) | 3kg | 5kg | 7kg | 10kg | 15kg | 20kg | 40kg | ||
Optional: High and low temperature test function | Temperature range | -65ºC~+150ºC | |||||||
Temperature rise and fall rate | B type nearly 2ºC/min; S type nearly 4ºC/min; E nearly 6ºC/min | ||||||||
Remarks | Above indicators are measured in no load at ambient temperature of 20±2°C(According to GB/T 5170.2-2017) | ||||||||
Inner dimensions | D | 350 | 400 | 500 | 600 | 650 | 800 | 1200 | |
W | 350 | 500 | 600 | 600 | 600 | 700 | 800 | ||
H | 400 | 500 | 500 | 550 | 550 | 900 | 1000 | ||
External dimensions | D | 2000 | 2250 | 2350 | 2550 | 1950 | 2200 | 2650 | |
W | 1400 | 1570 | 1670 | 1670 | 2700 | 3000 | 3000 | ||
H | 1950 | 2150 | 2150 | 2250 | 2300 | 2400 | 2600 | ||
Caster | 4, 6 for over 500L (caster dimension is not included in above overall dimension,caster rises by 60-120mm) | ||||||||
Test hole | OneΦ50 | OneΦ100 | |||||||
Stainless steel shelf (2 pcs in standard configuration) | Bearing 15kg/pc | Bearing 30kg/pc | Bearing 50kg/pc | ||||||
Using environment temperature | 0~+40ºC | ||||||||
Shell | Sprayed steel plate | ||||||||
Interior | SUS304 stainless steel | ||||||||
Cooling mode | water-cooling, (water temperature 7~28ºC, hydraulic pressure 0.2~0.4Mpa,To ensure cooling performance) | ||||||||
Controller | 7′ Color touch screen Controller | ||||||||
Communication function | RS485 or standard RJ45 network interface, standard USB interface | ||||||||
Power supply | 380V+10%/50HZ+1,three-phase-five-wire system (3P+N+G) | ||||||||
Meet the testing method | GJB150.5-2009, GB/T 2423-2008; The optional high and low temperature test function also meets the requirements of GB2423.1-2008, GB2423.2-2008, GJB150.3-2009, GJB150.4-2009. | ||||||||
Safety precautions | Power supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Heater short circuit protection, refrigeration unit overpressure/ overload/ oil shortage protection; humidifier fault protection; Overload/overheating protection for blower motor, overcurrent protection and leakage protection for control board; Cooling water shortage protection, gas source undervoltage protection, etc. | ||||||||
Optional | 1.Optional high and low temperature testing function; 2. Optional special test holes and special shelves; 3. Optional liquid nitrogen function. |