Temperature Shock Chamber with Cold and Heat Two Chambers Structure

Customization: Available
After-sales Service: After-Sales Service Available
Power Supply: 380V±10%/50Hz±1(3p+N+G)

Products Details

  • Overview
  • Product Description
  • Product Parameters
  • Centralized control
  • Certifications
  • Company Profile
  • Other Products
  • Cooperation Cases
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
JTSM-B/S/E Series
Certification
CE
Warranty
1 Year
Temperature Exposure Range
+50ºC~+150ºC
Temperature Fluctuation
± 0.5 ºC
Temperature Deviation
± 2 ºC
Temperature Uniformity
2 ºC
Transport Package
Wood Case
Specification
50L / 100L /150L / 200L / Customized
Trademark
Jupiter
Origin
China

Product Description

Temperature Shock Chamber with Two Chambers
Product Description

Introduction
Such a series of impact test chamber adopts a structure of cold and thermal chambers and utilizes a bucket rapidly transforming specimens to the test area, so as to conduct cold and thermal shock tests.

This impact mode reduces thermal load during cold and thermal impact and shortens temperature recovery time to the greatest extent.

Feature

  • This series chamber using cold and heat two chambers structure, mainly used for hot and cold temperature impact test material in an instant, in a very short period of time test caused by heat bilges cold shrink can bear by chemical or physical damage.
  • 7 inches large color touch screen program control, running status be clear at a glance.
  • The user can save 50 to edit test procedure, also has a record of 365 days parameter function (equipped with paperless recorder).
  • In accordance with the requirements of recovery time, automatic equipment precooling, preheating temperature, adjust the working status of test cases to be the best.
  • Low error, the wind speed is high, the uniform sample exposure.
  • Province energy consumption, low noise design.
  • Shopping basket conversion time is less than 10 seconds, temperature recovery time for 5 minutes.
  • High temperature and low temperature zone can be independently controlled respectively, three with a chamber.
  • GJB150.3, GJB150.4, GJB150.5 ...
Product Parameters
Parameters for all models 
Temperature Shock Chamber(Two Chamber)
Model JTS50M-B/S/E TS100M-B/S/E JTS150M-B/S/E JTS200M-B/S/E JTS320M-B/S/E JTS500M-B/S/E JTS1000M-B/S/E
Nominal inside volume(L) 50L 100L 150L 200L 320L 500L 1000L
Performance Parameter Heating chamber Temperature exposure range +50ºC~+150ºC
Upper limit of preheating temperature 200ºC
Heating time RT~+200ºC, B type: ≤ 50min; S type: ≤ 40min; E type: ≤ 30min
Cooling chamber Temperature exposure range B type: 0~-40ºC; S type: 0~-55ºC; E type: 0~-65ºC
Lower limit of pre cooling temperature -75ºC
Cooling time RT~+70ºC, B type: ≤ 60min; S type: ≤ 50min; E type: ≤ 40min
Hand basket Temperature shock range B type:-40ºC~+150ºC; S type: -55ºC~+150ºC; E type: -65ºC~+150ºC
Temperature fluctuation ≤±0.5
Temperature uniformity ≤2ºC
Temperature deviation ≤±2ºC
Conversion time ≤10s
Temperature recovery time 5 min
Load (steel) 3kg 5kg 7kg 10kg 15kg 20kg 40kg
Optional: High and low temperature test function Temperature range -65ºC~+150ºC
Temperature rise and fall rate B type nearly 2ºC/min; S type nearly 4ºC/min; E nearly 6ºC/min
Remarks Above indicators are measured in no load at ambient temperature of 20±2°C(According to GB/T 5170.2-2017)
Inner dimensions D 350 400 500 600 650 800 1200
W 350 500 600 600 600 700 800
H 400 500 500 550 550 900 1000
External dimensions D 2000 2250 2350 2550 1950 2200 2650
W 1400 1570 1670 1670 2700 3000 3000
H 1950 2150 2150 2250 2300 2400 2600
Caster 4, 6 for over 500L (caster dimension is not included in above overall dimension,caster rises by 60-120mm)
Test hole OneΦ50 OneΦ100
Stainless steel shelf (2 pcs in standard configuration) Bearing 15kg/pc Bearing 30kg/pc Bearing 50kg/pc
Using environment temperature 0~+40ºC
Shell Sprayed steel plate
Interior SUS304 stainless steel
Cooling mode water-cooling, (water temperature 7~28ºC, hydraulic pressure 0.2~0.4Mpa,To ensure cooling performance)
Controller 7′ Color touch screen Controller
Communication function RS485 or standard RJ45 network interface, standard USB interface
Power supply 380V+10%/50HZ+1,three-phase-five-wire system (3P+N+G)
Meet the testing method GJB150.5-2009, GB/T 2423-2008;
The optional high and low temperature test function also meets the requirements of GB2423.1-2008, GB2423.2-2008, GJB150.3-2009, GJB150.4-2009.
Safety precautions Power supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Heater short circuit protection, refrigeration unit overpressure/ overload/ oil shortage protection; humidifier fault protection; Overload/overheating protection for blower motor, overcurrent protection and leakage protection for control board; Cooling water shortage protection, gas source undervoltage protection, etc.
Optional 1.Optional high and low temperature testing function; 2. Optional special test holes and special shelves; 3. Optional liquid nitrogen function.
 
Centralized control

Temperature Shock Chamber with Cold and Heat Two Chambers Structure

 
Certifications

Temperature Shock Chamber with Cold and Heat Two Chambers Structure

Company Profile

Temperature Shock Chamber with Cold and Heat Two Chambers StructureTemperature Shock Chamber with Cold and Heat Two Chambers StructureTemperature Shock Chamber with Cold and Heat Two Chambers StructureTemperature Shock Chamber with Cold and Heat Two Chambers Structure

Other Products

Temperature Shock Chamber with Cold and Heat Two Chambers Structure

Cooperation Cases

Temperature Shock Chamber with Cold and Heat Two Chambers Structure

Packaging & Shipping
Temperature Shock Chamber with Cold and Heat Two Chambers StructureTemperature Shock Chamber with Cold and Heat Two Chambers Structure

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours